h(m) | Level 1 D=10m |
Level 2 D=30m |
Level 3 D=40m |
Level 4 D=60m |
---|---|---|---|---|
2 | 10 | 12 | 15 | 17 |
3 | 15 | 19 | 22 | 26 |
4 | 21 | 25 | 30 | 34 |
5 | 26 | 31 | 38 | 43 |
10 | 28 | 35 | 42 | 49 |
Prevectron 3 TS10
PREVECTRON 3® integrates patented OptiMax® technology for the first time: Developed by the Lightning Research Center LiRi, OptiMax® allows neutralization of spatial charges around the PDA tip before generating a rise indicator. It can then evolve in a perfectly controlled electrical environment.
This innovation results in a reduction in the order of 40% of the standard deviations measured in the laboratory high voltage: the lower the standard deviation, the higher the ascending tracker emission is stable and accurate. Reliability protection is enhanced.
Functional parameters
- Continuous measurement of the electric field gradient (ΔE/Δt)
- The patented OPTIMAX® technology optimizes shock-inducing
- Sparking of high voltage pulses
- 6 independent and synchronized modules
- Complex electrical continuity cross-section 315 mm2 - nickel-plated copper
- 316 stainless steel, electromagnetic shielding
- Patented tester
- Removable modules